MIMAKI JV5-160S Specifikace Strana 215

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 262
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 214
6-25
CHAPTER 6 Operation for Functions Invoking NCU functions
Invoking NCU functions
List of functions
This section describes briefly the NCU functions and their setting values.
Setting a NCU functions
The operation described below on the operation panel is required to execute NCU functions.
STEPS:
1 Make sure that the printer is in LOCAL mode, and then select [NCU] using the [FUNC-
TION] key and press the [ENTER] key.
If it is in REMOTE mode, press the [REMOTE] key once.
2 Select an NCU function and make setting.
Name Function Refer to
NOZZLE CHECK Set whether or not to perform nozzle missing detection. p. 6-26
NG ACTION (*1)
Set the operation of the printer to be performed in case the preset number of
or more missing nozzles are detected and thus NG judgment is made. (*2)
p. 6-26
NG JUDGEMENT (*1) Set the number of missing nozzles for NG judgment. (*2) p. 6-27
COND.INDICATION Displays the status of the NCU. p. 6-27
NG (*1): Bad nozzle condition.
NG (*2): One or more bad nozzles have been located on print head.
PRE PRT AFT
35°C 40°C 50°C
L. > [JV5-01]
width : ∗∗∗∗ mm
PRE PRT AFT
35°C 40°C 50°C
FUNCTION
NCU <ENT>
Zobrazit stránku 214