- 5.16 -
Execute the flushing and cleaning regularly [Routine Control]
This function allows for the pigment ink for textile (TPig).
Set time limits on the flushing and cleaning functions at regular time intervals to avoid nozzle
clogging and clean off dust on the nozzle surface.
Routine Flushing
The routine flushing function is executed with the power on.
Time set by the hour is available for 1 to 24 hrs with this function turns on.
STEPS:
1. Make sure that the FUNCTION mode is dis-
played.
2. Press the [
] or [ ] keys to select [MAINTE-
NANCE].
3. Press the [ENTER] key.
4. Press the [
] or [ ] keys to select [Routine
Ctrl].
5. Press the [ENTER] key.
6. Select [Routine Flushing], then press the [EN-
TER] key.
7. Press the [
] or [ ] keys to select [ON].
8. Press the [ENTER] key.
9. Press the [ ] or [ ] keys, and select time inter-
val. (1 to 24h)
10. Press the [ENTER] key.
FUNCTION
SETUP < ENT >
FUNCTION
MAINTENANCE < ENT >
MAINTENANCE
Station < ent >
MAINTENANCE
Routine Ctrl < ent >
Routine Control
Select : Flushing
Routine Flushing
Flushing : OFF
Routine Flushing
Flushing : ON
Routine Flushing
Interval = 1h
Routine Flushing
Interval = 2h
MAINTENANCE
Routine Ctrl < ent >